Equipped with a high-frequency X-ray generator that consistently produces high quality radiographs conducive to high quality X-ray output, with very small kV ripple and accurate mA and mAs. Designed to provide operator convenience and patient comfort.
The analog X-ray machine is designed for high processing volumes in hospitals, orthopedics, and medical imaging facilities. The stationary X-ray machine can perform a wide range of examinations while optimizing the productivity of technicians and patient workflow. Simplicity and functionality provide a wide range of positioning capabilities for patient surgery, and the DR system’s feature-rich controls and ease of use enable technicians to focus on patient care.
1. The use of high voltage resistance tube, kV, mA enough, the machine clarity and contrast is good.
2. It is especially suitable for all radiographic acquisition of patients in the lying and sitting position.
3. Provide excellent exposure quality to support any type of X-ray in radiology centers, clinics and hospitals, whether it is used for analog or digital imaging techniques.
4. The “floating” desktop for patient positioning has a very large range of longitudinal and horizontal motion.
5. Rotate 180 degrees vertically in four directions, lock automatically every 90 degrees, easily rotate the X-ray tube to achieve horizontal radiation.
6. Integrated console display kV, MA, output accurate working data.
7. Electromagnetic positioning and position indicator combined, accurate positioning, reliable movement.
8. Provide five versions, X-ray generator range of 20kW to 50kW, strong penetration, can deal with obese patients
Model | PLD7400-20R-A | PLD7400-20R-A1 | PLD7400-32R-A | PLD7400-40R-A | PLD7400-50R-A | |
X-ray Generator(include console) | Output Power | 20KW | 20KW | 32KW | 40KW | 50KW |
Power Voltage | 380V±38V/220V±22V | 380V±38V | 380V±38V/220V±22V | |||
kV range | 40~125kV | 40~150kV | ||||
mA range | 10~200mA | 32~320mA±10% | 32~400mA | 32~500mA | 10~630mA | |
mAs range | 0.5 ~320mAs | 0.32 ~400mAs | 0.32 ~500mAs | 0.1 ~630mAs | ||
Exposure time | 0.002~6.3S | |||||
X-ray Tube | Small focus | 140kHU | 240kHU | |||
Large focus | 1.0 | 0.6 | 1 | 0.6 | ||
Anode speed | 2.0 | 1.2 | 2.0 | 1.2 | ||
Radiographic Table | Top Table Size | 2100X800X650mm | ||||
Bucky Size | 18X18inch | |||||
Table longitudinal movement | ≥900mm | |||||
Cassette Movement Distance | ≥500mm | |||||
Vertical Chest Stand | Vertical moving range | ≥1200mm | ||||
Bucky Size | 18X18inch |