With the physical properties of saturated steam, a large amount of latent heat and moisture are released during condensation, and the object is maintained in a high temperature and humid environment in this case, and the main protein of bacteria will be solidified. Can kill bacteria. After sterilization, you must manually take the sterilized medical waste into the chamber of the pulverizer.
The equipment is widely used in pharmaceutical, medical, scientific and other industries for biological products, medical devices, sterile clothing, tools, utensils, medical and articular high temperature sterilization, cooling and drying processes.
Portable steam sterilizer shredder is used for shredding and sterilization of medical waste. Medical waste sterilization and crushing machine is suitable for laboratories, dialysis centers, clinics and hospitals. Its industrial shredding machine is integrated with autoclave, but medical waste shredder and autoclave are not integrated, shredding room and sterilization room are separate. Therefore, after sterilization, you must manually bring the sterilized medical waste to the chamber of the grinder for crushing. Use steam and electricity only for on-site treatment of highly infectious hospital waste, such as garbage bags, cardboard or rigid containers containing various surgical, medical and research and healthcare waste, such as sharp tools, gloves, laboratory appliances, glass, plastic/rubber pipes, filters, etc., without emission of hazardous substances. The sterilizing tank is 30L. The medical waste sterilizer adopts high-pressure and high-temperature steam to sterilize. Maximum sterilization temperature 126℃, each working cycle time is about 60-90 minutes, Industrial Shredder is driven by 1.5kW motor, cutting chamber size W330xL220mm. It has a capacity of about 30kg/hr.
1. The equipment is suitable for processing sharps, gloves, experimental utensils, glass, plastic, rubber pipes, filters and other highly infectious wastes in laboratories, dialysis centers, clinics, hospitals and other places.
2. Depending on the capacity, the whole process is basically automated except that the sterilized waste is transported manually by the sterilizing machine to the shredder. The total cycle time can be up to 15-35 minutes and up to 25 litres of clinical waste can be treated.
3. Medical waste is fragmented and non-toxic after treatment, and can be safely disposed of as ordinary municipal waste.
4. The use of high quality stainless steel container, in accordance with the pressure equipment directive, industrial shredder to reduce the volume and volume of waste material to 20%.
5. Industrial shredding machine is a cross-cutting two-axis shredding machine, with a powerful shredding blade, which can automatically reverse and clean the stuck waste.
6. Steam is generated by internal steam generator and drainage system as standard accessories.
7. The system includes a simple control panel, sterilization time, chamber temperature, chamber pressure, waste sterilization state can be set manually.
8. The control system ensures high reliability, simple operation, safety, and automatic cycle of biomedical waste process.
9. Integrated shredder and sterilizer have many safety features, including safety valve, thermostat, temperature sensor, water level detector, pressure sensor, automatic cutter reversal and software safety features.
10. Germicidal shredder reaches the highest standard in machinery, quality, safety and operation.
◆ Type: high temperature, high pressure, vacuum high pressure sterilization, supporting industrial mill;
◆ Sterilization temperature :+ 5 ~ 126°C.
◆ Microbial inactivation :99.99%.
◆ Rated power :3+ 1.5KW
◆ Process: before sterilization paper shredder
◆ Sterilization pressure: ≤ 0.17mpa
◆ Waste volume reduction: 60-80%
![]() |
|
![]() |
Model | WRAS-30 | ||
Shredder Part | Sterilizer Part | ||
Motor Power | 1.5 KW | Heating Power | 3 KW |
Chamber Size | 326x216x165 | Sterilization Temperature | +5-126℃ Optional |
Rotor-Knives Dia. | Φ176 mm | Heat Preservation Time | 1-99.59 min/h |
Rotor-Knives Thickness | 15 mm | Temperature Difference Inside | < 1 ℃ |
Shaft Speed | 22 Rpm | Chamber Size | Ø 388 x 400 |
Rotor-knives Number | 14 Pcs | Chamber Volume | 30 L |
Suggest Material Feeding Size | 250×250 mm | Sterilization pressure | ≤ 0.17 Mpa |
Auto Reverse To Clear The Jammed Material | Yes | Microbial Inactivation | 99.99% |
Output Flakes Size | < 30 mm | Process: | Sterilization prior to Shredding |
Whole Machine | |||
Machine Size | 1290x756x1215 mm | ||
Machine Weight | 650 KG | ||
Working Voltage | 220V/50Hz/1 Phase or Customized |