Zhangjiagang City, Jiangsu Province, China.
+86-512-58810663
Usage:
Orthopaedics:osteopathy, diaplasis, nailing
Surgery: removing foreign body, cardiac catheter, implanting pace maker, interventional therapy, partial radiography, local photography, and other work.
PLX118F Medical Digital C-arm Type X Ray Machine Features:
1. Adopt the advanced dynamic Plat Panel Detector, large field of view, high definition, large dynamic field, low noise, no image distortion, compact and convenience.
2. 9 inch* 9 inch effective image size, meet the demand of every part of various floroscopy in clinical application.
3. World-class image processing technology software makes the image more distinct to make it more convenient for the doctors in the operation and diagnostic process. Standard DICOM interface makes it convenient to connect with the hospital information system.
4. Optional grey LCD display, more higher definition, and excellent image quality
5. Own High Frequency generator technology,realize the high frequency pulse floroscopy and greatly reduce X-ray dose.
6. Unique double foot brake controller design makes it convenient to control the instrument inside and outside the operation room. This design can also protect the health care professionals by reducing the opportunity to come into contact with the radiation.
7. Exclusive inside and outside monitor design makes it more convenient to observe the operation process either inside or outside the operation room. At the same time, this design can facilitate the outdoor teaching and the real-time observation of the surgical procedures.
8. Uniquely designed basement electric auxiliary supporting arm, ensuring safer use.
9. Auto brightness tracking function .
10.Multi-protection and hint function of error code, easy and convenient for maintance.
11.New-pattern frame design with a small and pleasing shape.
Configuration:
1, New (with electric auxiliary support arm) C-arm host one set
2, High-frequency high-voltage X-ray generator and high-frequency inverter power
Category | Project | Content | ||
Photography Capacity | 5.0KW | |||
Automatic Fluoroscopy | Tube Voltage:40kV~120kV adjust automatically | |||
Tube Current:0.3mA~4mA adjust automatically | ||||
Manual Fluoroscopy | Tube Voltage:40kV~120kV Continuous | |||
Tube Current:0.3mA~4mA Continuous | ||||
Pulse Fluoroscopy | Tube Voltage:40kV~120kV Continuous | |||
Performance | Tube Current:0.3mA~30mA Continuous | |||
Pulse frequency: continuously, adjustable | ||||
Photography | Tube | 40 kV~120kV | 25-100mA | |
Voltage and mA | ||||
X-ray Tube | X-ray Tube Special for Fixed anode Dual-focus, small focus: 0.3 | |||
High Frequency | Inverter Frequency: 110KHz | |||
Type | A-si | |||
Scintilator | CSI |