When the airway pressure, the patient’s lung compliance change or pipeline micro leakage, the ventilator can automatically compensate for tidal amount. Advanced automatic control technology, high precision import sensor, control valve. There is no need to replace the bellows when used for children. 10.2-inch display, precise control, display various monitoring parameters
1.Integrated breathing circuit with APL valve, excellent tightness.
2.Replacing drive bellow is NOT required when operating adult/pediatric anesthesia.
3.Applied with 2 high-precision vaporizers. (Selectatec).
4.10.1 inch touch screen with no dead space.
5.Real-time detection for loops, Paw, BPM, VT and compliance.
6.Comprehensive monitoring capabilities include ventilation parameters monitoring,preset parameters, alarm indication and breathing waveform monitoring.
7.Head light.
8.Altitude compensation function.
9.ACGO available to connect with T/Bain circuit for open operation.
10Yoke system with up to 3 back up cylinders (A type with 11L size) or (Optional).
Technique Specifications | |
Physical Specifications | |
Dimensions: | 70*85*140cm |
Weight: | 65kg |
Casters: | Front wheels with lock |
Screen: | 10.1 inch LCD |
Working Specifications | |
Power | AC 100V-240v, 50Hz±2% |
Pipeline Supply | |
Gas configuration | O2, N2O, Air |
Pipeline input range | 280-600kPa |
Battery Power | |
Run-time | ^180 mins |
Pre-setting Functions | |
Language | English |
Calibration | Automatic |
Applications | |
Patient range | Audit/ Pediatric |
Ventilator Specifications | |
Modes of Ventilation | |
VCV | Volume Controlled Ventilation |
A/C | Assist / control Ventilation |
SIMV | Synchronized Intermittent Mandatory Ventilation |
MANUAL | Manual |
PCV | Pressure Control Ventilation |
PSV | Pressure Support Ventilation |
STAND-BY | STAND-BY |
Ventilator Parameter | |
Working type | Electronically controlled, pneumatic driven |
Tidal Volume range | 20-1500ml |
Pressure range | 5-60 CIT1H2O |
Rispriation rate range | 1-100 bpm (1-40bpm under SIMV) |
l:E range | 4:1-1:8 |
Ptrigger range | -20-20 cmH20 (based on PEEP) |
Flow trigger | 0-15L |
Minute volume range | >18L/Min |
SIGH range | 0-5/100 |
System Standard | |
Hypoxic guard system | N2O cut-off valve, O2 concentration >25% |
Safety valve | <12.5kPa |
Fresh gas compensation | 25-75L/min |
Volume of CO? absorber | 2L |
Flow meter | 5 tubes, Cascade 0.1-15L/min O2 |
0.1-15L/min N2O, 0.1-15L/min air | |
Vaporizer | 2 Selectetac, maximum 2 mounts(lsoflurane/Enflurane/Sevoflurane/Halothane) |
Monitoring | |
Display graphics | Waveforms of P-T, F-T, V-T, loops of P-V,V-F,F-P |
Types | VT, MV, BPM, Paw, Lung compliance, Inspiratory Platform,F1O2 |
Alarm Limits | |
Audio/Visual | No tidal volume, MV,Paw, F1O2 limitation O2, |
Air failure, AC power failure, Battery low | |
PEEP | |
Type | Integrated, Electronic control |
Range | OFF, 3-30cmH2O |
Optional | |
1. AGSS | |
2. Suction Unit | |
3.Communication Interface |