Zhangjiagang City, Jiangsu Province, China.
+86-512-58810663
The Air/Oxygen Blender is a precision proportioning device for mixing medical grade air and oxygen, which provides oxygen concentration and conveying gas flow controlled oxygen therapy for clinic. Besides as opened-end oxygen delivery, the Air/Oxygen Blender is supporting the use of infant incubator, infant radiant warmer, infant oxygen hood, oxygen therapy instrument, ventilator, CPAP, resuscitator and epidural instrument etc, especially suitable for neonatal intensive care unit and ward oxygen delivery (Forbidden for the high blood oxygen disease).
Performance Characteristics:
Oxygen concentration is 21%-100% continuous adjustable;
Oxygen concentration and flow rate is adjusted separately;
High precision regulating and continuous steady gas output;
Model & Specification HBKY-10A HBKY-10B Pneumatic control without power supply;
HBKY-30A and HBKY-30B can be used for two patients simultaneously.
Specification:
Oxygen concentration adjusting range and accuracy :
HBKY-10A and HBKY-10B: Oxygen concentration adjusting range: 21% -100% ;Accuracy: 3% 02 ( V/V ) .
HBKY-20A and HBKY-20B: Oxygen concentration adjusting range: 21% -100% ; Accuracy: 3% 02 ( V/V ) .
HBKY-30A and HBKY-30B : Oxygen concentration adjusting range: 21% -100% ; Accuracy: The accuracy of HBKY-30A and HBKY-30B blender is 3% 02 (V/V) when use the single flow and the flow rate is more than 4L/min ;
The accuracy of HBKY-30A and HBKY-30B blender is 6% 02 (V/V) when use the double flow and both sides flow rate are more than 4L/min.
Flow rate adjusting range: HBKY-10A, HBKY-10B, HBKY-30A and HBKY-30B: 0L/min -18L/min ;
Weight 0.84kg HBKY-20A and HBKY-20B: 0L/min -18L/min and 0L/min-3.5L/min. Input gas source pressure: 207kPa-517kPa.
Alarm of gas source : Single/double patient use Single patient use Gas supply pressure difference>138kPa ; Interruption of gas supply ;
Packing dimension Gas supply pressure >560kPa ;
The Air/Oxygen Blender is built-in pneumatic sound alarm device with the whistle sound ;
The alarm sound pressure level is>57dB(A).
Gross weight 3.0kg The Reverse Gas Flow of zero (The reverse gas flow from either gas inlet to the other is zero).
Model &specification | HBKY-10A | HBKY-10B | HBKY-20A | HBKY-20B | HBKY-30A | HBKY-30B |
Concentration valve | Single | Single | double | |||
Flow meter | Single | double | double | |||
Humidification bottle | No | Yes | No | Yes | No | Yes |
Gas bleed valve | Yes | Yes | No | |||
Main part dimension | 123 mm*68mm*71mm | 123 mm*68mm*71mm | 123 mm*68mm*71mm | |||
weight | 0.84kg | 0.84kg | 0.87kg | |||
Single /double patient use | Single patient use | Single patient use | Single /double patient use | |||
Packing | 315mm*300mm*265mm | |||||
Dimension | 3.0kg | 3.2kg | 3.6kg |