The Ventilator is a model of multi-purpose life-support machine. This machine uses the air operated electric control, the microcomputer technology. Selects imports the primary device to guarantee the equipment movement stably reliable. Colored (TFT) the screen demonstrates each kind of examination and the establishment parameter, which is a section of ideal breath treatment plant. It is suitable in all different levels of hospitals for internal medicine of surgery, gynecology, pedology, first aid, ICU and so on which are administrative offices equipments.
1. 12.1 inch touch screen with desirable color schemes
2. Support adult and pediatric ventilation mode
3. Multi-mode ventilation function (VCV, SIMV, PSV, PCV, APNEA, CPAP, Manual, SIGH)
4. The simplest interface boots a precise control and convenient operation
5. Air compressor support(optional)
6. Self testing and calibration
7. Auto-wash for exhaust valve
Technique Specifications | ||
Physical specifications | ||
Dimensions: | 45*55*140cm | |
Weight: | 65kg | |
Casters: | Front wheels with lock | |
Screen: | 12.1 inch touchable | |
Display | Colour LCD | |
Display graphics | Waveforms of P-T, F-T, V-T | |
Loops | P-V, F-V, F-P | |
Air compressor specifications | ||
Power | AC 220V±10%, 50Hz±2% | |
Output pressure | 0.4±0.1MPa | |
Noise | W50dB | |
Modes of ventilation | ||
VCV | Volume control ventilation | |
SIGH | SIGH | |
APNEA(A/C) | Assist Control | |
SIMV | Synchronized Intermittent Mandatory Ventilation | |
MANUAL | Manual | |
CPAP | Continuous Positive Airway Pressure | |
PSV | Pressure Support Ventilation | |
PCV | Pressure Control Ventilation | |
Ventilator parameter | ||
Tidal Volume range | 20-2000ml | |
Pressure range | 5-80 cmH2O | |
Rispriation Rate Range | 1-100 bpm (1-40 bpm under SIMV) | |
l:E Range | 4:1-1:8 | |
Oxygen concentration | 21%-100% | |
Ptrigger Range | -20~0cmH2O | |
Apnea Ti Range | 0-6s | |
PEEP | ||
Type | Integrated, Electronic control | |
Range | 0~40cmH2O | |
Alarm Limits | ||
Visual | No tidal volume, MV,Paw, FiO2 limitationO2 | |
Air failure, AC power failure, backup low | ||
Audio | No tidal volume, MV,Paw, F1O2 limitation | |
Pipeline supply | ||
Gas configuration | O2, Air | |
Pipeline input range | 280-600kPa | |
Battery Power | ||
Battery Type | Lead-acid 12V, 4Ah | |
Run-time | Typical 120 mins+ | |
Pre-setting functions | ||
Language | ENGLISH | |
Calibration | AUTOMATIC | |
Applications | ||
Patient therapy type | Audlt/Pediatric Invasive | |
Optional | ||
Air compressor | ||
SIMV/PSV ventilation mode | ||
BIPAP ventilation mode | ||
Environmental Conditions | ||
Operating Temp | 5 °C ~ 40 °C | |
Storage Temp | -10 °C~+40 °C | |
Humidity | ≤80% | |
Atmosphere pressure | 960 hPa-1040 hPa |