AM Series Medical Ampoule Leak Pulse Vacuum Steam Sterilizer Vertical Autoclave

Pulse Vacuum Steam Sterilizer provides steam sterilization for biology products, instruments, tools, dressings, sterile clothes etc with pulse vacuum. As first stage, these sterilizers adopt pulsation vacuum exhausting process to remove cold air influence to temperature. When sterilizing process finishes, these sterilizers adopt vacuum drying to dry the materials. These units have been proven in a wide range of material sterilizing including clothes, dressings, metal instruments and glass containers.

  • Product Description
  • Technical Parameters
  • Video

AM Series Medical Ampoule Leak Pulse Vacuum Steam Sterilizer Autoclave Introduction:
This series is a kind of high-performance and high-intelligence equipment for sterilizing, leak detecting and cleaning, which adopts colorful touching screen and PLC, applicable to treating of ampoule, oral medicine, small infusion bottle, etc. After sterilization, by means of vacuum or vacuum plus water, the detecting rate of waster is assured to be 100%.Finally washing treatment is carried out with clean water to ensure surface of bottle clean and uncontaminated.
Medical Steam Sterilizer, Medical Autoclave, Pulse Vacuum Steam Sterilizer, Ampoule Leak Sterilizer, Ampoule Leak Autoclave
Structure & Capability & Characteristics:
The boxes designed, produced and tested strictly according to the Steel Pressure Vessel
National patent sealing technology of inner gas
National patent door interlock
Reliable and stable micro-computer PLC touch screen control, advanced function for recording, printing and storing
Elegant stainless steel decorate cover
The heat preservation layer is made by polyurethane material and pearl rock wool
The GMP confirmation access is fixed on the equipment
Unique spraying cooling device
Medical Steam Sterilizer, Medical Autoclave, Pulse Vacuum Steam Sterilizer, Ampoule Leak Sterilizer, Ampoule Leak Autoclave

Main Parameters & Utilities

Design pressure 0.245Mpa Vacuum -0.095Mpa
Working Pressure 0.22Mpa Steam Source Pressure 0.4-0.6Mpa
Design Temperature 139℃ Water Source Pressure 0.1-0.3Mpa
Working Temperature 134℃ Compressed Air Pressure 0.5-0.7Mpa
Heat Equilibrium ≤±1℃

Size&Utilities

Specifications Model Overall Dimensions
L*M*H(mm)
Chamber Size
L*W*H(mm)
Steam Consumption
(kg/cycle)
Power
(KW)
Compressed Air
(m³/cycle)
Loading Cart(pcs) Cooling Water consumpation Net Weight
(kg)
AM-0.36 1195*1220*1720 1000*600*600 55 3 0.5 300 760
AM-0.6 1245*1300*1880 1050*680*850 75 3.5 0.8 400 1100
AM-1.2 1695*1370*1960 1500*750*1100 85 4 1.5 2 800 1900
AM-1.8 2445*1370*1960 2250*750*1100 100 4.5 2.0 3 1200 2450
AM-2.5 3195*1370*1960 3000*750*1100 180 6 3.0 4 1500 2800
AM-5.0 3635*1800*2200 3400*1000*1500 300 8 5.5 4 2500 4500

Note: The overall dimensions, chamber size, and the quantity of sterilizing car are for glass bottle. And there is a bit difference for soft bag.

Model 1ml 2ml 5ml 10ml 20ml
AM-0.36 32500 21000 8200 5500 33000
AM-0.6 64260 38880 17220 11160 6300
AM-1.2 127816 81664 33984 22400 11424
AM-1.8 191724 122496 50976 33600 17136
AM-2.5 255632 163328 67968 44800 22848
AM-5.0 605568 380160 158200 98208 50086