The neurosurgical head rack connects the patient’s head firmly and safely to the operating table. On the basis of ensuring the comfort and safety of the patient, placing the patient in a suitable position for the operation is conducive to the exposure of the operation field and reducing the difficulty of the operation.
The head rack is a special equipment for craniocerebral surgery. The head skull can be adjusted arbitrarily according to the needs of operation, such as back and forth, side to side swing, high and low, so as to obtain the appropriate head position and body position, facilitate the operation and anesthesia management, and play a reliable role in ensuring the smooth operation. 4 Point skull clamp is an indispensable and ideal tool for neuro surgery. The neurosurgical medical instruments connects the patient’s head firmly and safely to the operating table. On the basis of ensuring the comfort and safety of the patient, placing the patient in a suitable position for the operation head holder is conducive to the exposure of the operation field and reducing the difficulty of the operation.
1. One complete Set of instrument is composed of the base, skull fixture rack and U-Shaped head bracket. They can be assembled at will according to operation needs.
2. Adjustable cranial apical rack:
-Three-point fixation: the three points are distributed according to isosceles triangle, and the three points press the head synchronously to achieve stable fixation.
-Head clamp double bow streamline design, uniform stress conduction.
-Side single nail design is simple, no operating parts open vision.
-The interface should be fixed firmly. After locking with two nails on the side, there is no clearance, no shaking, and repeated use of non-slip wire.
-Intraoperative fine-tuning can be performed without loosening the patient’s head.
3. Head support: horseshoe shaped design, suitable for various head positions fixed function, adjustable size, smooth surface, soft texture.
4. Base: The inserting rod can be replaceable.
5. Can meet the supine, prone, side, sitting posture and other positions
6. The outer surface is treated with matte oxidation to prevent corrosion and aging, and the appearance of uniform color.
Main Parameters | |
Model | AOTA300 |
Forward and backward movement: | 350mm |
Left and right movement: | 400mm |
Height adjustable range: | 350mm |
Swinging angle: | ≥ 45° |
Adjustment range for Installation of center distance: | 190~400mm |
Packing(1pc/carton): | 430*400*160mm |
Gross weight: | 6kg |